328 Parameters
No.
Name/Value
50.07
FBA A actual 1 type
Speed or frequency Type and scaling is chosen automatically according to the
Transparent
General
Torque
Speed
Frequency
50.08
FBA A actual 2 type
Speed or frequency Type and scaling is chosen automatically according to the
Transparent
General
Torque
Speed
Frequency
50.09
FBA A SW
transparent source
Not selected
Other
50.10
FBA A act1
transparent source
Not selected
Other
Description
Selects the type and scaling of actual value 1 transmitted to
the fieldbus network through fieldbus adapter A. The scaling
of the value is defined by parameters 46.01...46.04,
depending on which actual value type is selected by this
parameter.
currently active operation mode as follows:
Operation mode
(see par. 19.01)
Speed control
Torque control
Frequency control
No scaling is applied.
Generic reference without a specific unit.
The scaling is defined by parameter
The scaling is defined by parameter
The scaling is defined by parameter
Selects the type and scaling of actual value 2 transmitted to
the fieldbus network through fieldbus adapter A. The scaling
of the value is defined by parameters 46.01...46.04,
depending on which actual value type is selected by this
parameter.
currently active operation mode as follows:
Operation mode
(see par. 19.01)
Speed control
Torque control
Frequency control
No scaling is applied.
Generic reference without a specific unit.
01.01 Motor speed used
is defined by parameter
The scaling is defined by parameter
The scaling is defined by parameter
Selects the source of the fieldbus status word when
parameter
50.06 FBA A SW sel
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.07 FBA A actual 1 type
Transparent, this parameter selects the source of actual value
1 transmitted to the fieldbus network through fieldbus adapter
A.
No source selected.
Source selection (see
Terms and abbreviations
Actual value 1 type
Speed
Frequency
46.03 Torque
46.01 Speed
46.02 Frequency
Actual value 2 type
Speed
Frequency
is sent as actual value 2. The scaling
46.03 Torque
scaling.
46.01 Speed
46.02 Frequency
is set to
Transparent
on page 162). -
is set to
on page 162). -
Def/FbEq16
Speed or
frequency
0
1
2
scaling.
3
scaling.
4
scaling. 5
Speed or
frequency
0
1
2
3
scaling.
4
scaling. 5
Not selected
mode.
-
Not selected
-