LH79524/LH79525 User's Guide
11.2.2.10 Resistor Configuration Control 6 Register (RESCTL6)
The RESCTL6 Register allows software to configure a number of the LH79524/LH79525
pull-up/pull-down resistors.
BIT
FIELD
RESET
RW
BIT
FIELD
RESET
RW
ADDR
Table 11-20. RESCTL6 Register
31
30
29
28
27
0
0
0
0
0
RO
RO
RO
RO
RO
15
14
13
12
11
0
0
0
0
0
RO
RO
RO
RO
RO
Table 11-21. RESCTL6 Fields
BIT NAME
31:4
///
Reserved Reading returns 0. Write the reset value.
Pin PB1/DREQ/nUARTRTS0 Resistor Assignment
00 = No Pull-Down or Pull-Up
3:2
PB1
01 = Pull-Down
10 = Pull-Up
11 = Reserved
Pin PB0/nDACK/nUARTCTS0 Resistor Assignment
00 = No Pull-Down or Pull-Up
1:0
PB0
01 = Pull-Down
10 = Pull-Up
11 = Reserved
26
25
24
23
///
0
0
0
0
RO
RO
RO
RO
10
9
8
7
///
0
0
0
0
RO
RO
RO
RO
0xFFFE5000 + 0x2C
DESCRIPTION
Version 1.0
I/O Configuration
22
21
20
19
18
0
0
0
0
0
RO
RO
RO
RO
RO
6
5
4
3
2
PB1
0
0
0
1
0
RO
RO
RO
RW
RW
17
16
0
0
RO
RO
1
0
PB0
1
0
RW
RW
11-13