15.2.2.19 Timer 2 Capture Registers (T2CAPn)

There are two T2CAPn Registers for Timer 2. They are designated:
• T2CAPA
• T2CAPB
Each register is a 16-bit, Read Only register. When a capture condition occurs, the con-
tents of the counter CNT2 are stored into the associated Capture Register. Capture Reg-
isters correspond to the input signals CTCAP2A through CTCAP2B, respectively. The
edge of the input signal used to trigger the capturing operation is determined by program-
ming the CTRL Register.
BIT
FIELD
RESET
RW
BIT
FIELD
RESET
RW
ADDR
BITS
31:16
15:0
15-28

Table 15-40. T2CAPn Register

31
30
29
28
27
0
0
0
0
0
RO
RO
RO
RO
RO
15
14
13
12
11
0
0
0
0
0
RO
RO
RO
RO
RO

Table 15-41. T2CAPn Register Definitions

NAME
Reserved Reading this field returns 0. Write the reset value.
///
CAPTURE2
Timer 2 Capture 16-bit Capture Register Value.
26
25
24
23
///
0
0
0
0
RO
RO
RO
RO
10
9
8
7
CAPTURE2
0
0
0
0
RO
RO
RO
RO
T2CAPA: xFFFC4000 + 0x68
T2CAPB: xFFFC4000 + 0x6C
DESCRIPTION
Version 1.0
LH79524/LH79525 User's Guide
22
21
20
19
18
0
0
0
0
0
RO
RO
RO
RO
RO
6
5
4
3
2
0
0
0
0
0
RO
RO
RO
RO
RO
17
16
0
0
RO
RO
1
0
0
0
RO
RO