Equipment Installation
Install Plug-In Unit
Figure 80
Inserting PIU
Step 5
Rotate the locking lever to the released position and gently press it in until the lever automatically starts to
move, as shown in the following figure.
Figure 81
Releasing Locking Lever
Step 6
Rotate the locking lever to the locked position to fully insert the PIU and lock it into place, as shown in the
following figure. Wait 1 minute after installing PIU before removing the PIU.
·
Release 19.1.1
Issue 1.1, May 2021
Lever
Lock