Adding L110 Blade To Roadm; Provision L110 Tributary Shelf, Slots, And Ports Using Webgui - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

ROADM Turn-Up and Operations

Adding L110 Blade to ROADM

7.12
Adding L110 Blade to ROADM
In this section:
7.12.1

Provision L110 Tributary Shelf, Slots, and Ports Using WebGUI

7.12.2
Provision L110 Tributary Blade OCH Interfaces
7.12.3
Provision Add/Drop Port Connections
7.12.4
Provision Cross-Connects
Perform initial setup for the tributary L110 Blade to be added as described in
Auto Shelf ID Assignment
Enabled.
Note: The default name must be changed from fujitsu for the system to turn up as well as for the tributary
shelves to be recognized.
7.12.1
Provision L110 Tributary Shelf, Slots, and Ports Using WebGUI
Step 1
Press the arrow icon that appears when hovering over an existing blade in the Equipment tree.
Step Result:
The /equipment:eqpt/shelf tab appears.
Step 2
Select the checkbox next to the BDL1-3B11 shelf.
Step Result:
The /equipment:eqpt/shelf("n") tab appears.
Note: The value "n" is the number of the shelf being provisioned.
Step 3
Select the slot tab.
Step 4
Press the add button (+ sign) in the slot tab.
Step Result:
The Add List Item dialog box opens.
Step 5
Select the slot number (1 or 2) from the slotID dropdown list and click Ok.
Step Result:
The slot is added to slot table.
·
Release 19.1.1
Issue 1.1, May 2021
Set Up Tributary Blade without
Fujitsu and Fujitsu Customer Use Only
271