System Maintenance
Trouble Clearing
thresholdCrossingAlertSeverelyErroredSeconds
Entity Type
Ether OSC (BDL1-3R11)
thresholdCrossingAlertSpanlossVariationTooHigh
Entity Type
PORT=E1 (BDL1-3R11)
thresholdCrossingAlertSpanlossVariationTooLow
Entity Type
PORT=E1 (BDL1-3R11)
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
■ Optical path problems exist between
the upstream node and the near end.
■ The blade has failed.
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
■ The threshold level is improperly set.
■ Attenuation on the existing span has
increased.
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
■ The threshold level is improperly set.
■ Attenuation on the existing span has
decreased.
Location
Description
NEND
The threshold for severely errored seconds
has been crossed.
Suggested Corrective Action
1. Check the optical output level at the upstream
transmitter.
2. Check the optical receive level at the input to the local
BDL1-3R11 blade.
3. Replace the blade.
Location
Description
NEND
The span loss variation is above the
threshold level.
Suggested Corrective Action
1. Verify the proper threshold levels with local standards.
If needed, reset the PM threshold to correct.
2. Follow local practices to check the physical
characteristics of the existing span.
Location
Description
NEND
The span loss variation is below the
threshold level.
Suggested Corrective Action
1. Verify the proper threshold levels with local standards.
If needed, reset the PM threshold to correct.
2. Follow local practices to check the physical
characteristics of the existing span.
Fujitsu and Fujitsu Customer Use Only
339