Entity Type
100ME
100ME
1GEBT
1GEBT
BDL1-3B11, BDL1-3R11,
1GEX, 1GEBT
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
minor
non–service-
n/a
affecting
Probable Cause
■ The SFP module installed in the
specified port is mismounted.
■ The SFP module does not match the
port for which it is provisioned.
critical
service-
n/a
affecting
Probable Cause
■ The SFP module installed in the
specified port is mismounted and has an
interface provisioned on it.
■ The SFP module does not match the
port for which it is provisioned and has
an interface provisioned on it.
warning
non–service-
n/a
affecting
Probable Cause
■ The SFP module installed in the
specified port is mismounted.
■ The SFP module does not match the
port for which it is provisioned.
minor
non–service-
n/a
affecting
Probable Cause
■ The SFP module installed in the
specified port is mismounted.
■ The SFP module does not match the
port for which it is provisioned.
major
non–service-
n/a
affecting
Probable Cause
The interblade communication cables are
not installed correctly.
Location
Description
NEND
Mismatch of Equipment and Attributes:
TYPE=<unit type>
Suggested Corrective Action
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
NEND
Mismatch of Equipment and Attributes:
TYPE=<unit type>
Suggested Corrective Action
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
NEND
Mismatch of Equipment and Attributes:
TYPE=<unit type> and the admin-status is
down
Suggested Corrective Action
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
NEND
Mismatch of Equipment and Attributes:
TYPE=<unit type>
Suggested Corrective Action
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
NEND
Interblade communication Miscabled
Connection: TYPE = <unit type>
Suggested Corrective Action
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.