Initial System Turn Up

Provision L100 Tributary Blade and Ports

5.12
Provision L100 Tributary Blade and Ports
Note: The default name must be changed from fujitsu for the system to turn up as well as for the tributary
shelves to be recognized.
Step 1
Provision the L100 tributary blade equipment.
Note: If autoprovisioning is enabled, the L100 tributary blade equipment is automatically provisioned.
Command:
% set eqpt shelf 2 type BDL1-3R11 shelf-mode NORMAL shelf-role TRIB admin-status up
Step 2
Provision the Fan unit slots.
Note: If autoprovisioning is enabled, the Fan unit slots are automatically provisioned.
Commands:
% set eqpt shelf 2 slot FAN1 cardType AC00-F011 admin-status up
% set eqpt shelf 2 slot FAN2 cardType AC00-F011 admin-status up
Step 3
Provision the E1 port on the L100 tributary blade.
Note: If autoprovisioning is enabled, the E1 port is automatically provisioned.
Command:
% set eqpt shelf 2 slot 0 cardType BDL1-3R11 subslot 0 port E1 admin-status up
pluggableInterfaceType Edge num-lanes 128
Step 4
Provision the client ports (C1...C9) on the L100 tributary blade.
Note: If autoprovisioning is enabled, the client ports (C1...C9) are automatically provisioned.
Command:
% set eqpt shelf 2 slot 0 cardType BDL1-3R11 subslot 0 port C1 admin-status up
pluggableInterfaceType Client num-lanes 128
Note: Repeat this step for each client port (C1...C9) to be provisioned.
Step 5
Provision the logical port.
·
Fujitsu and Fujitsu Customer Use Only
Release 19.1.1
Issue 1.1, May 2021