428
Equipment Removal
Remove Plug-In Unit
Locked
Released
Figure 168
Releasing PIU
Step 5
Carefully and slowly remove the PIU from the blade.
Plug-In Unit
Figure 169
Removing PIU
Step 6
After PIU is removed, inspect the PIU for any damage or debris. Carefully remove any debris. If the PIU is
damaged, follow local practice/procedures for repair or replacement of a damaged PIU, as applicable.
Step 7
Store the PIU in ESD-protective packaging.
Step 8
If a new PIU is to be installed in the same position, follow the appropriate PIU installation procedure. Wait 15
seconds before inserting the new PIU in the same position.
Note: If any PIU slots on an active blade are unoccupied, install filler panels in the unused slots.
·