Thresholdcrossingalertoscopticalreceivepowertoolow; Thresholdcrossingalertoscopticaltransmitpowertoohigh; Thresholdcrossingalertoscopticaltransmitpowertoolow - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

System Maintenance
Trouble Clearing

thresholdCrossingAlertOscOpticalReceivePowerTooLow

Entity Type
PORT=E1 (BDL1-3R11)

thresholdCrossingAlertOscOpticalTransmitPowerTooHigh

Entity Type
PORT=E1 (BDL1-3R11)

thresholdCrossingAlertOscOpticalTransmitPowerTooLow

Entity Type
PORT=E1 (BDL1-3R11)
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
Optical OSC receive power is too low.
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
Optical OSC transmitter power is too high.
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
Optical OSC transmitter power is too low.
Location
Description
NEND
The optical receive power at the OSC port is
below the threshold level.
Suggested Corrective Action
1. Verify that the appropriate transmitter is installed at
the far end.
2. Verify that the transmit output level at the far end is
within specifications. Replace the transmitter if the
level is too low.
3. Clean fiber connections in the path.
Location
Description
NEND
The optical transmit power at the OSC port
is above the threshold level.
Suggested Corrective Action
Replace the blade if necessary.
Location
Description
NEND
The optical transmit power at the OSC port
is below the threshold level.
Suggested Corrective Action
1. Verify that the transmit output level is within
specifications.
2. Replace the blade if necessary.