Thresholdcrossingalerterroredseconds; Thresholdcrossingalertopticalreceivepowertoohigh - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

System Maintenance
Trouble Clearing

thresholdCrossingAlertErroredSeconds

Entity Type
Ether OSC (BDL1-3R11)

thresholdCrossingAlertOpticalReceivePowerTooHigh

Entity Type
EQPT
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
■ Optical path problems exist between
the upstream node and the near end.
■ The blade has failed.
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
Optical receive power is too high.
Location
Description
NEND
The threshold for errored seconds has been
crossed.
Suggested Corrective Action
1. Clean the optical connectors.
2. Check the optical receive level at the input to the local
blade.
3. Clear outstanding lossOfSignal alarms to clear the PM
counts.
4. Replace the blade.
Location
Description
NEND
The optical receive power level is above the
threshold on one of the following ports:
■ For BDL1-3R11:
• E-SC-E1
• F-SC-E1
• LCN1...4
■ For BDL1-3B11: LCN1...4
Suggested Corrective Action
1. Verify that the appropriate transmitter is installed at
the far end.
2. Verify that the transmit output level at the far end is
within specifications.
3. Install an appropriate optical attenuator in the line at
the receiver.