System Maintenance
Trouble Clearing

equipmentShelfProvisioningMode

Entity Type
COM

equipmentWarmup

Entity Type
BDL1-3R11
PIL1-3PS2
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
warning
non–service-
n/a
affecting
Probable Cause
The shelf provisioning mode is incorrect.
Service
Severity
Direction
Affected
warning
non–service-
n/a
affecting
Probable Cause
The blade is in a warm-up condition
following power-up.
warning
non–service-
n/a
affecting
Probable Cause
The PIU is in a warm-up condition following
insertion.
Location
Description
NEND
The shelf provisioning mode is set to an
incorrect value.
Suggested Corrective Action
1. If the blade is set to factory defaults in a new turn-up,
initiate a WARM reset to make this blade the Main
blade.
2. For a tributary blade in a new turn-up, change the
shelf type to TRIB.
3. If the NE is carrying traffic and the shelf provision
command is sent by accident, cancel the shelf
provisioning command to clear the condition.
Location
Description
NEND
Equipment Warm-Up: TYPE = <unit type>
Suggested Corrective Action
No action is required. The condition appears after the
facility is provisioned, and the condition clears when the
unit achieves the desired output wavelength.
NEND
Equipment Warm-Up: TYPE = <unit type>
Suggested Corrective Action
No action is required. The condition appears after the
facility is provisioned, and the condition clears when the
unit achieves the desired output wavelength.
Fujitsu and Fujitsu Customer Use Only
310