System Maintenance
Trouble Clearing

firmwareVersionMismatch

Entity Type
BDL1-3B11, BDL1-3R11
BDL1-3B11, BDL1-3R11

forwardDefectIndication

Entity Type
och
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
minor
service-
n/a
affecting
Probable Cause
The FW on the tributary blade specified in
the alarm is not compatible with the system
software.
major
service-
n/a
affecting
Probable Cause
The FW on the tributary blade specified in
the alarm is not compatible with the system
software.
Service
Severity
Direction
Affected
warning
service-
receive
affecting
Probable Cause
An OCH signal failure, for example, a WDM
LOS, has occurred in the upstream direction.
Location
Description
NEND
Firmware Version Mismatch: TYPE = <unit
type>
Suggested Corrective Action
Perform the FW upgrade procedure on the indicated blade.
NEND
Firmware Version Mismatch: TYPE = <unit
type>
Suggested Corrective Action
Perform the FW upgrade procedure on the indicated blade.
Location
Description
NEND
Forward Defect Indication
Suggested Corrective Action
Clear the upstream WDM transmit signal failure.
Caution: The OSC must be active for traffic to be restored.
A failure of the OSC may keep traffic from recovering on a
span.