System Maintenance
Trouble Clearing
equipmentRemoved
Entity Type
AC00-F011
AC00-F011
PIL1-3PS2
PIL1-3PS2
1GEX
1GEX
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
minor
non–service-
n/a
affecting
Probable Cause
A Fan unit has been removed.
critical
service-
n/a
affecting
Probable Cause
Both Fan units have been removed.
minor
non–service-
n/a
affecting
Probable Cause
The PIU is not properly seated or has been
removed.
critical
service-
n/a
affecting
Probable Cause
The PIU is not properly seated or has been
removed and has at least one interface
provisioned on it.
minor
non–service-
n/a
affecting
Probable Cause
The SFP module is not properly seated or
has been removed.
critical
service-
n/a
affecting
Probable Cause
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Location
Description
NEND
Equipment Removed: TYPE=<unit type>
Suggested Corrective Action
Replace the Fan unit.
NEND
Equipment Removed: TYPE=<unit type>
Suggested Corrective Action
Replace the Fan units.
NEND
Equipment Removed: TYPE=<unit type>
Suggested Corrective Action
Reseat or replace the PIU. If a PIU is not required in the slot
generating the alarm, the alarm can be cleared by deleting
the equipment slot.
NEND
Equipment Removed: TYPE=<unit type>
Suggested Corrective Action
Reseat or replace the PIU. If a PIU is not required in the slot
generating the alarm, the alarm can be cleared by deleting
the equipment slot.
NEND
Equipment Removed: TYPE=<unit type>
Suggested Corrective Action
Reseat or replace the SFP module. If a SFP module is not
required in the port generating the alarm, the alarm can be
cleared by deleting the equipment port.
NEND
Equipment Removed: TYPE=<unit type>
Suggested Corrective Action
Reseat or replace the SFP module. If a SFP module is not
required in the port generating the alarm, the alarm can be
cleared by deleting the equipment port.