System Description and Engineering
Engineering Specifications
Table 5 (Cont.)
General Specifications
Property
Power consumption
1.8.4

L160 Specifications

Table 6
Engineering Specifications
Property
Weight
Dimensions (H x W x D)
Operating temperature range
Storage temperature range
Short-term temperature range
Operating humidity range
Short-term humidity range
Input voltage
Power consumption
L160 Raman Blade Operational Requirement Considerations
■ Minimum outside plant fiber distance is 40 km
■ Minimum span loss is 15 dB
■ Optical return loss is >17.6 dB
·
Release 19.1.1
Issue 1.1, May 2021
Specification
■ Typical: 177.50 W (calculated)
■ Maximum: 237.30 W (calculated)
Note: The power consumption includes the power consumption for
the blade with 2 Fan units and 2 PIUs installed.
Specification
19.8 lb (9.0 kg)
1.75 x 19.00 x 17.72 in. (44.45 x 483.00 x 450.00 mm)
Note: The depth dimension is without the fiber management. The
depth dimension with fiber management is less than 23.62 in. (600
mm).
5...40 °C
–40...70 °C
–5...50 °C (96-hour period, maximum of 15 days/year)
5...85%
5...93% (96-hour period, maximum of 15 days/year)
■ Minimum: –40 V DC
■ Maximum: –57 V DC
■ Typical: 127.4 W (calculated)
■ Maximum: 230.7 W (calculated)