System Maintenance
Backup and Restore
Step 8
Log on to the LMP and check the shelf is in shelf provisioning mode.
Command:
> show alarms alarm-list | tab
Output:
alarms alarm-list number-of-alarms 3
alarms alarm-list last-changed 2019-08-06T20:27:01.616938+00:00
LAST
PERCEIVED
NOTIFICATION
CIRCUIT
RESOURCE
ALARM TYPE ID
CHANGE
TEXT
-----------------------------------------------------------------------------------
-----------------------------------------------------------------------------------
-----------------------------------------
COM
noSecondaryDatabase
2019-08-06T20:26:56.405191+00:00
Database
COM
shelfProvisioningMode
2019-08-06T20:27:01.569386+00:00
Mode
COM
databaseLockedShelfProvModePresent
2019-08-06T20:27:01.616938+00:00
Provisioning Mode Present
If YES:
Proceed to
Step
10.
If NO:
Continue with next step.
Step 9
Set the replacement L100 Blade to shelf provisioning mode.
Command:
> request set-shelfmode reset
Note: The shelf reboots and the user needs to log back onto the blade.
Step 10
Retrieve alarms to verify the blade is in shelf provisioning mode.
Command:
> show alarms alarm-list | tab
·
Release 19.1.1
Issue 1.1, May 2021
SEVERITY
LAST ALARM
minor
warning
false
warning
false
true
ALARM TYPE QUALIFIER
AFFECTING
ENABLED
not-applicable near-end
No Secondary
false
true
not-applicable near-end
Shelf Provisioning
true
-
not-applicable near-end
Database System Locked: Shelf
421
LAST IS
SERVICE
LAST STATUS
ID
-
Fujitsu and Fujitsu Customer Use Only