System Maintenance
Trouble Clearing
Entity Type
Port (Client)
Port (OSC)
1GEX
1GEX
1GEX
1GEX
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
critical
service-
receive
affecting
Probable Cause
The optical power on the indicated transmit
edge subport is too low.
major
non–service-
receive
affecting
Probable Cause
The optical power on the indicated transmit
edge port is too low.
minor
non–service-
transmit
affecting
Probable Cause
The optical power on the indicated transmit
1GEX interface is too low.
minor
non–service-
receive
affecting
Probable Cause
The optical power on the indicated transmit
1GEX interface is too low.
critical
service-
transmit
affecting
Probable Cause
The optical power on the indicated transmit
1GEX interface is too low.
critical
service-
receive
affecting
Probable Cause
The optical power on the indicated receive
1GEX interface is too low.
Location
Description
NEND
Power Out of Specification–Low: TYPE =
<unit type>
Suggested Corrective Action
Check the optical transmit power at the indicated port.
NEND
Power Out of Specification–Low: TYPE =
<unit type>
Suggested Corrective Action
Check the optical transmit power at the indicated port.
NEND
Power Out of Specification–Low: TYPE =
<unit type>
Suggested Corrective Action
None
NEND
Power Out of Specification–Low: TYPE =
<unit type>
Suggested Corrective Action
Check the optical transmit power at the indicated interface.
NEND
Power Out of Specification–Low: TYPE =
<unit type>
Suggested Corrective Action
Check the optical transmit power at the indicated interface.
NEND
Power Out of Specification–Low: TYPE =
<unit type>
Suggested Corrective Action
Check the optical receive power at the indicated interface.