Fujitsu 1FINITY L100 User Manual page 19

Table of Contents

Advertisement

• EN 62368-1:2014 (Audio/video, information and
communication technology equipment—Part 1: Safety
requirements (IEC 62368-1:2014, modified))
• IEC/EN 60825-1 (Safety of laser products—Part 1:
Equipment classification and requirements)
• IEC/EN 60825-2 (Safety of laser products—Part 2: Optical
fibre communication systems [OFCS])
■ The following symbol identifies the terminal intended for
connection to an external conductor for protection against
electrical shock in case of a fault, or the terminal of a protective
earth (ground) electrode.
Laser Safety Classification and Caution
The 1FINITY L160 Blade is compliant with the Laser IEC/EN 60825-1, 2 standards.
Class 1 Caution
CLASS 1 LASER PRODUCT
Hazard Level 1M Caution
HAZARD LEVEL 1M LASER RADIATION
DO NOT VIEW DIRECTLY WITH NON-ATTENUATING OPTICAL INSTRUMENTS
Laser Safety Information
The L160 (BDL1-3M21) C-Band Raman uses Laser Class 1M and Hazard Level 1M optical interface units in accordance with the following
standards:
■ IEC 60825-1:2007(Ed.2)/EN 60825-1:2007 (Laser class information)
■ IEC 60825-1:2014(Ed.3)/EN 60825-1:2014 (Laser class information)
■ IEC 60825-2:2010(Ed.3.2)/EN 60825-2:2004/A2:2010 (Hazard level information)
Radiation output of classification information:
Output of laser radiation: 0.1 mW (Value can be changed after laser safety compliance test)
Note: The use of an aperture specified as condition 3 limits the amount of radiation that is collected from a large diameter
(measurement distance = 100 mm).
Emitted wavelengths: 1504.5...1566.93 nm
Beam divergence: 0.25 rad