Provision Add/Drop Port Connections - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

269
ROADM Turn-Up and Operations
Adding Degree to ROADM Node
Step 2
Provision the OTS interface.
Command:
% set interfaces interface ots-2/0/0/E1 type opticalTransport ots circuit-id OTS-2
fiber-type smf degree-number 2 operation-mode owb-fj-base admin-status up
Step 3
Provision the OMS interface.
Command:
% set interfaces interface ots-2/0/0/E1 type opticalTransport ots oms circuit-id
OMS-2
Step 4
Provision the OCH interface.
Command:
% set interfaces interface ots-2/0/0/E1 type opticalTransport ots oms och 1 center-
frequency 196.10 slot-width 50
Step 5
Repeat the preceding step for each OCH interface (1...96) to be provisioned.
Step 6
Verify the interfaces are provisioned correctly.
Command:
% show interfaces
Continue with the next task.
7.11.3

Provision Add/Drop Port Connections

Step 1
Provision an ADD connection between a PIL1-3PS2 edge port and the L100 client port.
Command:
% set port-connection PORT-ADD src-shelf 3 src-slot 1 src-subslot 0 src-port E1
dst-shelf 1 dst-slot 0 dst-subslot 0 dst-port C1
Step 2
Provision a DROP connection between the L100 client port and a PIL1-3PS2 edge port.
Command:
% set port-connection PORT-DROP src-shelf 1 src-slot 0 src-subslot 0 src-port C1
dst-shelf 3 dst-slot 1 dst-subslot 0 dst-port E1
Step 3
Repeat the preceding steps for each ADD/DROP connection to be provisioned.
·
Fujitsu and Fujitsu Customer Use Only
Release 19.1.1
Issue 1.1, May 2021

Advertisement