System Maintenance
Trouble Clearing
Entity Type
AC00-F011
BDL1-3B11, BDL1-3R11,
1GEX, 1GEBT
PIL1-3PS2
PIL1-3PS2
BDL1-3B11, BDL1-3R11,
1GEX, 1GEBT
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
minor
non–service-
n/a
affecting
Probable Cause
■ A Fan unit is mismounted.
■ A Fan unit slot is not provisioned
correctly.
major
non–service-
n/a
affecting
Probable Cause
The interblade communication cables are
not installed correctly.
warning
non–service-
n/a
affecting
Probable Cause
■ The PIU installed in the specified slot is
mismounted.
■ The PIU does not match the slot for
which it is provisioned.
minor
non–service-
n/a
affecting
Probable Cause
■ The PIU installed in the specified slot is
mismounted.
■ The PIU does not match the slot for
which it is provisioned.
major
non–service-
n/a
affecting
Probable Cause
The interblade communication cables are
not installed correctly.
Location
Description
NEND
Mismatch of Equipment and Attributes:
TYPE=<unit type>
Suggested Corrective Action
1. Remove and remount the Fan unit.
2. Correct the Fan unit slot provisioning.
NEND
Interblade communication Miscabled
Connection: TYPE = <unit type>
Suggested Corrective Action
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
NEND
Mismatch of Equipment and Attributes:
TYPE=<unit type> and the admin-status is
down
Suggested Corrective Action
1. Remove and remount the PIU module.
2. Replace the PIU module with the correct PIU module.
NEND
Mismatch of Equipment and Attributes:
TYPE=<unit type>
Suggested Corrective Action
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
NEND
Interblade communication Miscabled
Connection: TYPE = <unit type>
Suggested Corrective Action
1. Remove and remount the PIU.
2. Replace the PIU with the correct PIU.
Fujitsu and Fujitsu Customer Use Only
305