Huawei SmartAX MA5603T Configuration Manual page 125

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Item
Battery high-
temperature
power-off
parameters
Environment
monitoring
parameters
External
extended
digital
parameters
Issue 01 (2014-04-30)
Data Plan for the F01D500
Cabinet
Battery high-temperature power-
off permission status: permit
Temperature for battery high-
temperature power-off: 53°C
Upper alarm threshold of the
temperature: 68°C
Lower alarm threshold of the
temperature: -5°C
Upper test threshold of the
humidity: 80°C
Lower test threshold of the
humidity: -20°C
Digital parameter ID: 0
This digital parameter is set
according to the actual
requirements. The monitoring
digital parameter of the external fan
tray is set here to monitor the fan
tray. When the fan tray is faulty, the
host reports an alarm.
Valid level of digital parameter 0:
low level
When the low level represents the
valid level, the host does not report
an alarm in the case of low level.
Digital parameter ID: 1
This digital parameter is set
according to the actual
requirements. The monitoring
digital parameter of the external fan
tray is set here to monitor the fan
tray. When the fan tray is faulty, the
host reports an alarm.
Valid level of digital parameter 1:
low level
When the low level represents the
valid level, the host does not report
an alarm in the case of low level.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1 Commissioning
Data Plan for the N66 Cabinet
Battery high-temperature power-off
permission status: permit
Temperature for battery high-
temperature power-off: 53°C
Upper alarm threshold of the
temperature: 68°C
Lower alarm threshold of the
temperature: -5°C
Upper test threshold of the humidity:
80°C
Lower test threshold of the humidity:
-20°C
Digital parameter ID: 0
This digital parameter is set according
to the actual requirements. The
monitoring digital parameter of the
external fan tray is set here to monitor
the fan tray. When the fan tray is faulty,
the host reports an alarm.
Valid level of digital parameter 0: low
level
When the low level represents the valid
level, the host does not report an alarm
in the case of low level.
Digital parameter ID: 1
This digital parameter is set according
to the actual requirements. The
monitoring digital parameter of the
external fan tray is set here to monitor
the fan tray. When the fan tray is faulty,
the host reports an alarm.
Valid level of digital parameter 1: low
level
When the low level represents the valid
level, the host does not report an alarm
in the case of low level.