Huawei SmartAX MA5603T Configuration Manual page 214

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
To...
Query events by event
type
Query events by event
class
Query events by event
level
Query events by event
time
Query events by event
parameter
Query all the latest
events
Procedure
Step 1 Perform an operation (such as inserting and removing a board) to generate an alarm or event.
Step 2 Run the display alarm history command to query history alarms.
Step 3 Run the display event history command to query history events.
----End
Result
You can query the alarm or event triggered by the operation you have performed.
Example
To query the history environment alarms by alarm type, do as follows:
huawei>display alarm history alarmtype
{ type<E><communication,service,process,equipment,environment> }:environment
{ <cr>|detail<K>|list<K>|start-number<U><1,1900>||<K> }:list
{ <cr>||<K> }:
Command:
------------------------------------------------------------------------
AlarmSN
------------------------------------------------------------------------
777
765
764
Issue 01 (2014-04-30)
Run the Command...
display event history eventtype type [ detail | list | start-number
number]
display event history eventclass class [ detail | list | start-
number number]
display event history eventlevel level [ detail | list | start-
number number]
display event history eventtime start start-date start-time end end-
date end-time [ start-number number ] [ detail | list | start-
number number]
display event history eventparameter { frameid/slotid/portid |
frameid/slotid | frameid | vlanif vlanif } [ detail | list ]
display event history all [ detail | list ]
display alarm history alarmtype environment list
Date&Time
2009-08-21 10:18:29
2009-08-21 10:17:29
2009-08-21 10:17:29
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Alarm Name/Para
The system resources usage recovers from
the overload state to the normal state
Resource Name: CPU, Current Percent: 70
The system resources usage exceeds the
threshold
Resource Name: CPU, Current Percent: 86
The system resources usage recovers from
the overload state to the normal state