SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Monitoring Parameter
Displayed on the Host
Wiring alarm
Battery Tem
environment Tem/
environment Hum
NOTE
Configuration Process
The monitoring parameters can be reported to the control system only when the data for the
GEPS4845 is configured correctly in the system.
Table 1-32
Table 1-32 Commands for configuring the GEPS4845
To...
Add an EMU
Query the configuration
parameters of the power system
Query the power environment
parameters
Query the alarm information of
the power supply
Configure the battery charging
parameters
Configure the battery
management parameters
Configure the upper/lower
temperature alarm limits or the
upper/lower temperature test
limits
Configure the power supply load
power-off and battery set power-
off parameters
Issue 01 (2014-04-30)
Before adding a user-defined analog or monitoring digital parameter, make sure that the port corresponding
to this parameter is properly connected to an environment monitoring cable.
lists the commands used during the configuration.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Device Port
JTP1
BAT_WE
TEM-HU
Run the Command...
emu add
display power system parameter
display power environment parameter
display power alarm
power charge
power battery parameter
power battery temperature
power off
1 Commissioning
Application in the F01D500
Cabinet
MDF
Battery temperature sensor
Temperature and humidity sensor
104