Huawei SmartAX MA5603T Configuration Manual page 346

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
huawei(config-if-sip-0)#reset
Are you sure to reset the SIP interface?(y/n)[n]:y
huawei(config-if-sip-0)#quit
Step 6 Query the running status of the SIP interface.
After the SIP interface is interconnected with the IMS, the SIP interface should be in the normal
state, indicating that the SIP interface can work in the normal state.
huawei>display if-sip all
------------------------------------------------------------
MGID
Transfer Mode
State
Signalling IP
Signalling Port
Primary Proxy IP 1/DomainName
Primary Proxy Port
Primary Proxy State
Secondary Proxy IP 1/DomainName
Secondary Proxy Port
Secondary Proxy State
Current Proxy
------------------------------------------------------------
Step 7 Configure the PSTN subscriber data.
1.
2.
3.
4.
5.
Step 8 Configure the PSTN port attributes.
Configure the PSTN port in slot 0/3 so that the port supports the polarity reversal.
huawei(config)#pstnport
huawei(config-pstnport)#pstnport attribute batset 0/3/0 0/3/63 reverse-pole-pulse
enable
huawei(config-pstnport)#quit
Step 9 Save the data.
Issue 01 (2014-04-30)
Configure the PSTN user data (Phone 0-Phone 63) in slot 0/2.
huawei(config)#esl user
huawei(config-esl-user)#sippstnuser batadd 0/2/0 0/2/63 0 telno 83110000
Configure the calling priority of the PSTN user in port 0/2/0 as Cat2.
huawei(config-esl-user)#sippstnuser attribute set 0/2/0 priority cat2
Configure the PSTN user data (Phone 64-Phone 127) in slot 0/3.
huawei(config-esl-user)#sippstnuser batadd 0/3/0 0/3/63 0 telno 88110000
Configure the authentication data of the PSTN user in port 0/2/0.
huawei(config-esl-user)#sippstnuser auth set 0/2/0 telno 83110000 password-
mode password
User Name(<=64 characters, "-" indicates deletion):user83110000
User Password(<=64 characters, "-" indicates deletion):
password pwd8311000
NOTE
Considering users safety, the IMS may require user authentication. You can run the sippstnuser auth set
command to configure the user authentication data, including user name, password mode and password.
The authentication data should be consistent with that of IMS side.
Configure the PSTN user type in slot 0/3.
huawei(config-esl-user)#sippstnuser attribute batset 0/3/0 0/3/63 potslinetype
PayPhone
huawei(config-esl-user)#quit
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Configuring the DSLAM Services
0
UDP
Normal
192.168.0.170
5068
192.168.0.171
5060
Up
192.168.0.172
5061
Up
Primary Proxy
//Input the
321

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5600tSmartax ma5608t

Table of Contents