Item
Issue 01 (2014-04-30)
Data Plan for the F01D500
Cabinet
Digital parameter ID: 2
This digital parameter is set
according to the actual
requirements.
Valid level of digital parameter 2:
low level
When the low level represents the
valid level, the host does not report
an alarm in the case of low level.
Digital parameter ID: 3
This digital parameter is set
according to the actual
requirements. The monitoring
digital parameter of the surge
protector is set here to monitor the
status of the surge protector. When
the surge protector is faulty, the
host reports an alarm.
Valid level of digital parameter 3:
low level
When the low level represents the
valid level, the host does not report
an alarm in the case of low level.
Digital parameter ID: 4
This digital parameter is set
according to the actual
requirements. The monitoring
digital parameter of the smoke
sensor is set here to monitor
whether there is smoke in the actual
environment. When there is smoke,
the host reports an alarm.
Valid level of digital parameter 4:
high level
When the high level represents the
valid level, the host does not report
an alarm in the case of high level.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1 Commissioning
Data Plan for the N66 Cabinet
Digital parameter ID: 2
This digital parameter is set according
to the actual requirements.
Valid level of digital parameter 2: low
level
When the low level represents the valid
level, the host does not report an alarm
in the case of low level.
Digital parameter ID: 3
This digital parameter is set according
to the actual requirements. The
monitoring digital parameter of the
surge protector is set here to monitor the
status of the surge protector. When the
surge protector is faulty, the host
reports an alarm.
Valid level of digital parameter 3: low
level
When the low level represents the valid
level, the host does not report an alarm
in the case of low level.
Digital parameter ID: 4
This digital parameter is set according
to the actual requirements. The
monitoring digital parameter of the
smoke sensor is set here to monitor
whether there is smoke in the actual
environment. When there is smoke, the
host reports an alarm.
Valid level of digital parameter 4: high
level
When the high level represents the valid
level, the host does not report an alarm
in the case of high level.
101