The system is referenced to an energy-saving profile (that is, the unused board is shut down). If
a board is not used 15 minutes after it is confirmed and functions properly, the board is powered
off automatically.
Example
To reference energy-saving profile 4 to enable the system energy-saving function, do as follows:
Assume that battery energy saving is enabled and energy saving for unused boards is enabled.
huawei(config)#spm-profile profile-id 4
huawei(config-spm-prof-4)#unused-slot shutdown enable
huawei(config-spm-prof-4)#battery energy-saving ac-monitor emuid 1 digitalid 6
huawei(config-spm-prof-4)#battery energy-saving enable
huawei(config-spm-prof-4)#quit
huawei(config)#system energy-saving mode profile-id 4
huawei(config)#display system energy-saving mode
Current spm-profile id
Current spm-profile name: spm_profile_4
Issue 01 (2014-04-30)
You can recover the power supply of the board that is automatically powered off in the
following three ways:
– Run the board power-on command to power on the board.
– Remove the board from the slot that is automatically powered off, and the system
determines that the board is offline and then recovers the power supply of the slot. After
the power supply is recovered, reinstall the board.
– The system periodically (every 15 minutes) polls all boards that are automatically
powered off, and determines whether the boards can be powered on. If the boards meet
the power-on requirements, the system automatically powers on the boards.
Set the manual energy-saving mode.
1.
Run the board power-off command to manually power off a board.
Set the automatic energy-saving mode.
1.
Run the spm-profile command to create an energy-saving profile. By default, the
system uses the standard energy-saving profile. That is, the energy-saving mode is
disabled by default. You can enable the required energy-saving measure according to
actual requirements.
– Run the battery energy-saving command to set the status of the mains monitoring
module and battery energy saving.
– Run the unused-port shutdown command to set energy saving for unused ports.
– Run the unused-slot shutdown command to set energy saving for unused boards.
2.
Run the system energy-saving mode command to set the used energy-saving profile.
3.
Run the display system energy-saving mode command to query the used energy-
saving profile.