SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Procedure
Step 1 Set the DIP switches of the sub-nodes for the FAN. By default, the sub-node ID is 1.
NOTE
Step 2 Insert the fan tray into the corresponding slot of the service shelf.
Step 3 Run the emu add command to add a FAN. By default, the sub-node ID is 1.
Step 4 Run the interface emu command to enter the FAN mode.
Step 5 Run the fan speed mode auto or fan speed mode manual command to set the fan speed
adjustment mode. By default, the fan speed adjustment mode is automatic.
NOTE
Step 6 Run the fan alarmset command to configure the fan alarm reporting function. The fan alarms
are read temperature failure alarm, fan block alarm, over temperature alarm, and power fault
alarm. By default, the fan alarm reporting is permitted.
Step 7 Run the save command to save the data.
----End
Result
l
l
l
Example
To add a FAN, and adopt the default settings for the speed adjustment mode and alarm function,
do as follows:
huawei(config)#emu add 0 FAN 0 1 FAN
huawei(config)#interface emu 0
huawei(config-if-fan-0)#display fan system parameter
EMU ID: 0
FAN configration parameter:
----------------------------------------------------------------------------
FAN timing mode: Auto timing by temperature
----------------------------------------------------------------------------
Alarm_name
Issue 01 (2014-04-30)
The FAN communicates with the MA5600T/MA5603T/MA5608T in the master node and sub-node mode.
Therefore, the DIP switches of the sub-nodes for the FAN must be consistent with those for the MA5600T/
MA5603T/MA5608T. For details about how to configure the DIP switches of the FAN, see the Description
of DIP Switches in
1.3.1.2 Checking the Settings of DIP Switches on the Fan Monitoring
Description of DIP Switches in
Board
applies only to the MA5600T/MA5603T/MA5608T, but does not apply to the MA5608T.
When the fan speed adjustment mode is the manual mode, you can run the fan speed mode manual
command to set the fan speed. The speed level can be 0, 1, 2, 3, 4, 5 or 6. Here, 6 stands for the highest
level, and 0 stands for the lowest level.
In the FAN mode, run the display fan system parameter command to query the parameter
configuration of the fan tray and ensure that the configuration is the same as the data plan.
In the FAN mode, run the display fan environment info command to query the running
status of the fan tray and ensure that it is the same as the data plan.
In the FAN mode, run the display fan alarm command to query the alarm information
reported by the fan tray. The status of all the fan alarms is normal.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1.3.1.2 Checking the Settings of DIP Switches on the Fan Monitoring
Permit/Forbid
1 Commissioning
Board. The
126

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5600tSmartax ma5608t

Table of Contents