Commissioning The Emu_Fan - Huawei SmartAX MA5603T Configuration Manual

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Example
To add a TCU (emuid: 2; sub-node: 7), and set the heating start temperature to -10°C and the
heating stop temperature to 30°C for heat exchanger 2, do as follows:
huawei(config)#emu add 2 TCU 0 7 tcu
huawei(config)#interface emu 2
huawei(config-if-tcu-2)#tcu heat temperature
{ start-temperature<F><-90,40> }:-10
{ end-temperature<F><-90,40> }:30
Command:
Send command to environment monitor board ,please wait for a moment
huawei(config-if-tcu-2)#
Execute command successful

1.3.16.11 Commissioning the EMU_FAN

This topic describes how to commission the FAN to ensure that it monitors the environmental
conditions of the fans of the device according to the actual conditions.
Context
NOTE
The FAN is used to monitor the running status of the fans and to set the fan rotation speed
according to actual conditions to ensure the normal heat dissipation of the device.
When commissioning the FAN, pay attention to the following points:
l
l
l
Table 1-41
Table 1-41 Default configuration of the FAN
Parameter
Sub-node
Fan speed
adjustment mode
Whether to report
the fan alarm
Issue 01 (2014-04-30)
tcu heat temperature -10 30
When the device is delivered, the EMU_FAN is correctly connected to the shelf. The connection need not
be changed for the device commissioning. In certain cases, if the EMU needs to be configured in other
shelves, reconnect the EMU. For details, see this topic.
The EMU sub-nodes are numbered from 0 to 31.
When the system is configured with multiple EMUs simultaneously, make sure that the
sub-nodes do not conflict with each other.
It is recommended that you use the auto mode as the fan speed adjustment mode.
lists the default configuration of the FAN.
Default Value
1
Automatic
Permit
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1 Commissioning
125

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5600tSmartax ma5608t

Table of Contents