Item
Voice user data
(The data
configuration
must be the
same as the data
configuration
on the MGC.)
Procedure
l
Issue 01 (2014-04-30)
(Optional) Configuring the TID
Format of an MG Interface
Slot of the voice service board
Configuri
ng the
PSTN
User Data
Configure VAG1.
1.
Add the upstream VLAN interface.
According to the data plan, configure standard VLAN 20 as the media and signaling
upstream VLAN, add upstream port 0/19/0 to the VLAN, and configure the IP address
of the Layer 3 interface to 10.10.10.10, which facilitates the configuration of the media
and signaling IP address pools.
huawei(config)#vlan 20 standard
huawei(config)#port vlan 20 0/19 0
huawei(config)#interface vlanif 20
huawei(config-if-vlanif20)#ip address 10.10.10.10 24
huawei(config-if-vlanif20)#quit
2.
Configure the media and signaling IP address pools.
Add the IP address of the VLAN Layer 3 interface configured in the previous step to
the media and signaling IP address pools respectively. Therefore, the media and
signaling IP addresses used for the services can be selected from the IP address pools.
According to the data plan, IP address 10.10.10.10 is added to the media and signaling
IP address pools, and the gateway IP address corresponding to the media IP address
is 10.10.10.1.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Data
To differentiate users according to the
TID, the office requires that the
terminal prefix uses the community
name huawei and the TID is
automatically generated by the system
according to the subrack ID/slot ID/port
ID (F/S/P) of the user.
Run the display tid-template
command to query the default TID
template. It is found that default TID
template (template 6) can meet the
requirements.
User access is implemented by the
ASPB board in slot 0/2 and 0/3.
Phone number
The emergency standalone is not
supported, and therefore the phone
numbers do not need to be configured
when the users are added.
The MGC assigns phone numbers
83110000-83110031 to phones 0-31.
TID
The terminal layering is supported, and
therefore the TIDs do not need to be
allocated manually.