NEC NEAX2400 IPX Programming Manual page 931

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

D-67
D-67
General Description
This feature automatically prevents interruptions from features such as ATTENDANT CAMP-ON WITH TONE
INDICATION - CCIS [A-45], BUSY VERIFICATION - CCIS [B-9], and EXECUTIVE RIGHT-OF-WAY - CCIS
[E-8] during data transmission through the CCIS network.
Operating Procedure
term
Data Connection (D
activated (Data Adapter/Data Module), DATA PRIVACY - CCIS is set automatically. When the data transmission
has finished, DATA PRIVACY is automatically cancelled.
Service Conditions
1.
The following connections are restricted when DATA PRIVACY - CCIS is active because transmitted
tones are involved in their operation.
ATTENDANT CAMP-ON WITH TONE INDICATION
BUSY VERIFICATION
EXECUTIVE RIGHT-OF-WAY
If these features are attempted, a reorder tone will be received.
2.
DATA PRIVACY - CCIS cannot prevent disruptions in data transmission generated from outside the
CCIS network.
3.
When the data call disconnects, DATA PRIVACY - CCIS is automatically cancelled.
4.
When DATA PRIVACY - CCIS is activated, the circuit cannot be accessed by any PBX feature.
5.
This feature cannot be activated at a Tandem Office in the CCIS network.
6.
DATA PRIVACY - CCIS must be set at both communicating offices in the CCIS network.
Interactions
DATA PRIVACY - CCIS is the disallowing of the EXECUTIVE RIGHT-OF-WAY [E-1, E-8], BUSY
VERIFICATION [B-3, B-9], and ATTENDANT OVERRIDE [A-7] features. All of the above options will provide
the desired effect.
Programming
Per-Route Basis
ARTD - Assign CDN 44:PRV as data "1", Line Privacy.
Per-Station Basis
ASFC - Leave data "0" to SFI 4 and SFI 11 to the SFC assigned to the stations.
Per-Tenant Basis
ASYD - System Data 2, Index 0, Bits 2, 3, & 4. Assign data "0".
Page 888
Data Line Privacy - CCIS
Data Line Privacy - CCIS
- Data Adapter/Data Module): No manual operation is required. When a data call is
[A-1, A-45]
[B-3, B-9]
[E-1, E-8]
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1

Advertisement

Table of Contents
loading

Table of Contents