FCCS Programming (cont'd)
Index 68, b3: Enables automatic cancel timer
0/1 = -/Automatic cancel timer is Available
Index 159: Designate Automatic Cancel Timer
STEP 2:
ASPAN - These data must be assigned to the NCN.
TN:
Tenant Number
ACC: Access number
CI:
B = Busy (for Entry), N = Normal (for Cancel)
SRV:
SSC
SID:
19 = OG Queuing-Entry
CI:
N = Normal
SID:
20 = OG Queuing-Cancel
Note 1:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
The current data should also be set in addition the above-mentioned command:
Note 2:
The command to be set to the node that accommodates the trunk: ARTD
The command to be set to all the nodes: ASFC, AKYD
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Inter-Office Off-Hook Queuing