O-13
O-13
General Description
1.
When a call has terminated to UCD [U-1] Group A, and the incoming call has encountered all stations
busy in Group A, the call is transferred to UCD [U-1] Group B, if Group B is registered as the
OVERFLOW-UCD destination.
2.
If all stations are busy in Group B, then the call is placed in queue for the originally called UCD [U-1]
group (Group A).
Operating Procedure
No manual operation is required.
Service Conditions
1.
An OVERFLOW group must be a UCD [U-1] Group.
2.
One OVERFLOW group can be provided for one UCD [U-1] Group.
3.
OVERFLOW is performed only once.
4.
An OVERFLOW group cannot be registered into a queue.
Page 566
Overflow - UCD
Overflow - UCD
UCD
Group A
All Busy
Call Termination
Overflow
UCD
Group A
All Busy
Call Termination
Overflow
UCD
Group B
Call registered in Group A
Group B
All Busy