M-23
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ANPDL - Reserve a number level for feature access and cancel. Assign Connection Indexes, CI = N,
H, B; Normal (N), Hooking (H), and Busy (B) (applicable to any feature assigned to this level). Assign
NND in accordance with a predetermined numbering plan.
STEP 2:
ASPAL - Assign an access code to activate MESSAGE WAITING LAMP SETTING-ATTENDANT
SRV = SSCA (Service Code Appendix); SIDA = 54 and to extinguish the MESSAGE WAITING
LAMP SETTING-ATTENDANT SRV = SSCA (Service Code Appendix); SIDA = 55. Assign the
Connection Status Index (CI) for Normal (N) service.
Page 490
Message Waiting Lamp Setting - Attendant
NEAX2400 IPX Feature Programming Manual