System Data 1, Index 32, Bit 6. Is the number sent or number dialed recorded in SMDR? 0/1: Number
Sent/Number Dialed.
System Data 1, Index 33. Assign this index for Split Billing. If Split Billing is used, assign 00H. If
Total Billing is used, Bits 3 & 4 represent the following: 00: Telephone called first. 01: Telephone
called last. 10: Telephone receiving call from an Attendant Console.
Bit 5 must be assigned as data "1" to provide total billing for incoming calls.
Bit 6 must be assigned as data "1" to provide total billing for outgoing calls.
System Data 1, Index 34. Assign data 01H or 21H. Bit 0 enables RS-232C transmission.
System Data 1, Index 157. Outgoing Trunk, Soft Hold Timer. The point in time when the system will
recognize an outgoing call as answered. Default is 18 seconds. Because of interaction with momentary
pressing of the hook-switch, this data may be reassigned as 31H for 2 seconds. Take the SMDR aspect
into consideration when reassigning this data.
System Data 1, Indexes 288-295
Designation of the attributes of the SMDR.
SMDR output port will be designated. For this designation, the attributes of the terminal that outputs
the detail call information should have been designated by indexes 117-123. (Assigned by the AIOC
command.)
Also for detecting a fault of the SMDR, set the SMDR fault detect timer.
Index 288 = Charging information port of SMDR A.
Bit 4:
Bit 5:
Index 289 = SMDR fault detect timer of SMDR A.
Index 290 = Charging information port of SMDR B.
Bit 4:
Bit 5:
Index 291 = SMDR fault detect timer of SMDR B.
Index 292 = Charging information port of SMDR C.
Bit 4:
Bit 5:
Index 293 = SMDR fault detect timer of SMDR C.
Index 294 = Charging information port of SMDR D.
Bit 4:
Bit 5:
Index 295 = SMDR fault detect timer of SMDR D.
System Data 2, Index 3. Bit 0 enables SMDR registration per tenant.
System Data 2, Index 3. Optional assignments for station-to-station connection. Bit 6, 0/1: Calling &
Called output/Called output only. Bit 7, 0/1: -/SMDR Output (STN-STN) is in service.
STEP 2:
ASYDL - System Data 1, Index 576
Bit 0. Centralized Billing-Fusion (Polling Method): 0/1 = Not/To be provided. Required both for
Center Node and each Local Node.
Bit 1. SMDR for station to station connections in a self node 0/1=output/not output
Bit 2. 0 = RS-232C interface is used.
System Data 1, Index 577.
Fusion Point Code (FPC) of Center Node.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Station Message Detail Recording (SMDR)
IOC Equipment Number (0/1=No.0/No.1)
Expanded SMDR Output (0/1=Out/In Service)
IOC Equipment Number (0/1=No.0/No.1)
Expanded SMDR Output (0/1=Out/In Service)
IOC Equipment Number (0/1=No.0/No.1)
Expanded SMDR Output (0/1=Out/In Service)
IOC Equipment Number (0/1=No.0/No.1)
Expanded SMDR Output (0/1=Out/In Service)