NEC NEAX2400 IPX Programming Manual page 261

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

C-33
Programming
ASYD - System Data 1, Index 229, Bit 2. DTMF signal sending with the keypad pressed after the
attendant has answered an incoming call 0/1: Out/In Service.
System Data 3, Index 11. Assign a Miscellaneous Timer counter for the duration of the DTMF Sender
Tone. 128ms X (PBST + 1) = Duration of Sender Tone. Maximum value is 2.048 seconds.
Page 218
Consecutive Dialing - Attendant
7
6
5
4
3
2
PBST
1
0