NEC NEAX2400 IPX Programming Manual page 62

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

Programming (cont'd)
STEP 3:
ARTD - Assign the announcement route as shown below. Be sure to provide privacy by programming
CDN 44:PRV as data "1".
RT: 1
1-OSGS
8-RLP
STEP 4:
ARSC - Assign a Route Restriction Class (RSC) to the station that allows access to the Announcement
route. Assign RSC 0 to the Attendant, and allow that RSC access to the Announcement route.
STEP 5:
ATRK - Assign the LEN Number, Announcement Trunk Route Number. Assign one or more trunks to
a specific route used to connect to an announcement machine.
STEP 6:
MBTK - Assign the Make Idle status to the announcement trunk.
STEP 7:
ARRC - If TIE Line, DID, or REMOTE ACCESS TO PBX [R-2] connection to the Announcement
Service trunk is required, allow trunk-to-trunk connection using ARI-D-RES=1 (Direct Connection is
allowed.)
STEP 8:
AAED - This command is used to assign announcement equipment.
Dead Level:
Assign:
TN:
Tenant Number
EQP:
(Announcement Equipment Number) = 0 (Dead Level). For example, level 8 is not assigned
an announcement is returned rather than a reorder tone.
RT, TK:Route and Trunk number of the trunk connected to the announcement equipment.
Unused Number:
Assign:
TN:
Tenant Number
EQP:
1 (Unused Number). For example: EXT-7836 is not in the system. An Announcement is
returned rather than a reorder tone.
RT, TK:Route and Trunk number of the trunk connected to the announcement equipment.
Announcement Service:
Assign:
TN:
Tenant Number
EQP:
= 2 - 15
RT, TK:Route and Trunk number of the trunk connected to the announcement equipment.
C:
Duration of Connection, 0/1:Disconnection occurs in 30 seconds / Connection is held until the
station releases. See the requirements of the application for the announcement equipment. For
Dead Level applications, data 0 is assigned.
R:
Sending RBT 0/1: sending RBT/not sending RBT.
A:
Answer Signal Sending, 0/1: no answer from Incoming trunk/Answer from Incoming trunk.
Normally assign data "1".
M:
Multiple Connection 0/1: Single Connection/Multiple Connection. Usually assign for single
connection.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Announcement Service
:2
2-ONSG
:3
:2
15-LSG
:4
5-TF
:1
6-TCL
A-15
:1
7-L/T
:1
Page 19

Advertisement

Table of Contents
loading

Table of Contents