NEC NEAX2400 IPX Programming Manual page 87

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

A-30
Interactions (cont'd)
3.
The AICD Command must be assigned before the AKYD command.
4.
When assigning the PRI parameter in AKYD, the following data selections are available.
PRIORITY PRI
0
1
3
3
4
5.
No programming is required to enable the SIG key to remain active at all times.
6.
The SIG key, when pressed by a calling station, will interrupt other ringing signals at the called station.
7.
Hands-Free operation is available with AUTOMATIC/MANUAL INTERCOM. When an incoming call
terminates to a station, by pressing the SPEAKER key, the line seized is based on the PRI assignment of
the AKYD command.
8.
MANUAL SIGNALING [M-47] will not operate if the DATA key has been pressed.
Programming
STEP 1:
ASYD - System Data 1, Index 59, Bit 7. Is AICM/MICM in service? 0/1: No/Yes.
System Data 1, Index 69, Bit 6. Is a Warning Tone required when creating a 3-Way AICM/MICM
call? 0/1: No/Yes.
System Data 3, Index 3. Assign the data 20H for the burst ringing (for Automatic Intercom) if
necessary.
System Data 3, Index 7. Assign the Ringing Pattern (for Automatic Intercom) if necessary.
STEP 2:
AICD - Assign the following data:
MG:
Module Group
G-ID: Group ID Number per MG
A/M:
Automatic/Manual Signaling (0/1)
0: Automatic
1: Manual
BCR: Bridge Call Restriction (0/1)
0: Restricted
1: Allowed
TN:
Tenant Number
ICM STN:Intercom Station Number
SIG STN:Signaling Station Number
STEP 3:
AKYD - Assign a station INTERCOM Line according to the following parameters:
TN:
1
STN:
Station Number
TP:
Type of D
Page 44
Automatic/Manual Intercom
1
Prime Line
Dial Intercom
Automatic Intercom
Manual Intercom
Automatic Intercom
term
0/1:
2
-
Prime Line
Prime Line
Prime Line
Manual Intercom
NEAX2400 IPX Feature Programming Manual
3
-
-
-
-
Prime Line
NDA-24297, Issue 1