W-1
Programming (cont'd)
STEP 5:
ASPA - Assign the access code as assigned in ANPD above. Type of Service, SRV = OGC (Outgoing
Call) Outgoing Trunk. Assign the route number associated with this access code.
STEP 6:
ARSC - The Route Restriction Class must be constructed to allow the station access to the involved
routes.
Page 796
WATS Access
NEAX2400 IPX Feature Programming Manual