S-106
Programming (cont'd)
Assignment of Slumber Time Data
ASLU2 -
G =
[x] Slumber Time Group Number (1-7)
CNT =
[x] Count of Assigned Transfer Destination/Time Data
TFR 1/2: Transfer to attendant/announcement machine
FROM = [x] Slumber Time Start Time
TO =
[x] Slumber Time End Time
Note:
If the Slumber service is required 24 hours a day, enter the same time data in to both the "From Hour/From
Minute" parameters and to "To Hour/To Minute" parameters.
STEP 6:
ASFC - Allow Slumber Time Override to the SFC of the station which performs Slumber Time
Override. (SFI = 107, RES = 1)
STEP 7:
ARTD - Assign the following route class data to the route number of the trunk which performs
Slumber Time Override.
CDN 109:SLOV = 1
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
The station to use the service is registered by Physical Station Number in ASLU1 command.
STEP 2:
The identical ASLU2 data should be programmed at all FCCS nodes.
By assigning the data, this service is available for the incoming calls to be dialed telephone number.
Page 724
Slumber Time - Do Not Disturb
Note
Assign as many data as
assigned by CNT
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1