NEC NEAX2400 IPX Programming Manual page 584

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

Programming
STEP 1:
ASYD - System Data 1, Index 147. DIT supervisory timer for a busy station. How often will the CPU
look at the Idle/Busy status of the station for rerouting the DIT call to the destination? Always leave
this index as 00H.
For NIGHT CONNECTION-FIXED Only.
STEP 2:
ACSI - Assign Route Number, Trunk Number, Connection Service Index of "4" for NIGHT
CONNECTION-FIXED, and the Tenant Number and Station Number to serve as the NIGHT
CONNECTION-FIXED station.
STEP 3:
ACFR - Allow a Transfer Service Feature Index of 2, NIGHT CONNECTION-FIXED, for the types
of incoming calls listed in Call Class Index (CCI).
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ACSIL - This command must be assigned to the node accommodating the COT. Assign the logical
route number (LGRT), trunk number, and Connection Service Index (CSI)=4 for DIT activated in
Night mode. Then assign the user group number (UGN) and Telephone Number to serve as the
NIGHT CONNECTION - FIXED station.
Note 1:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
Note 2:
The current data should also be set in addition the above-mentioned command. The command to be set to
the node accommodating the COT: ASYD/ACFR.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Night Connection - Fixed
Note 1
N-1
Page 541

Advertisement

Table of Contents
loading

Table of Contents