Automatic Idle Return - NEC NEAX2400 IPX Programming Manual

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

A-69
General Description
This feature enables a D
the opposite station on-hook, etc., on hands-free or the speaker operation.
Operating Procedure
No manual operation is required.
Service Conditions
1.
This service may be assigned at each terminal.
2.
This service is not available when the station has a call placed on hold.
3.
This service is activated when reorder tone is sent to a D
4.
Release timer for this service can be set on a system basis.
5.
Reorder tone is connected according to System Data 1, Index 401, Bits 0 through 3. When the data is set
to 0, no tone is connected. For stations not allowed this service, reorder tone is connected 30 seconds after.
Interactions
1.
OFF-HOOK ALARM [O-6]: AUTOMATIC IDLE RETURN cannot be activated when OFF-HOOK
ALARM has already been set. However, when the transferred station assigned by OFF-HOOK ALARM
is in the LINE LOCKOUT [L-3] status or make busy status, AUTOMATIC IDLE RETURN is available.
2.
When a station places the other party on CALL HOLD [C-6], CALL BACK [C-1] or ATT CAMP-ON
WITH TONE INDICATION [A-1], AUTOMATIC IDLE RETURN may not be activated.
Programming
STEP 1:
ASYD - System Data 1, Index 401, Bits 0 through 3. Assign the timer value for AUTOMATIC IDLE
RETURN.
STEP 2:
ASFC - For stations allowed AUTOMATIC IDLE RETURN, assign a Class of Service that allows
SFI 136.
FCCS Programming
No unique programming is required for the FCCS network.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1

Automatic Idle Return

Automatic Idle Return
term
to become idle automatically after the predetermined time when the line is released by
term
individually.