NEC NEAX2400 IPX Programming Manual page 84

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

FCCS Programming (cont'd)
STEP 2:
ASPAL - For SRV = SSC (Service Code) SID = 42, assign the access code. For the NND parameter,
no assignment is required when AUTHORIZATION CODE [A-20] operates by itself. When Account
Code [A-18] operates with AUTHORIZATION CODE - TIE LINE INCOMING ROUTES, assign for
SRV = SSC (Service Code), SID = 42. The NND value will include the number of digits in the
AUTHORIZATION CODE access code, and Account Code.
Procedure 1 is not available with AUTHORIZATION CODE - TIE LINE INCOMING ROUTES.
Note:
For SRV = LCR (Least Cost Route Selection) / LCRS (Register Sender LCR), if operating Procedure 2
is used, (dialing the AUTHORIZATION CODE after the number dialed), assign data "1" to the AH
parameter when programming the LCR(S) access code. Therefore, operating Procedure 2 is only
available with LEAST-COST ROUTING - 3/6 DIGIT [L-5].
STEP 3:
LATCL - List all the AUTHORIZATION CODES. This is the simplest way to determine what digits
have been added to the system with the Checksum method. This is not required if the Checksum
method is not used.
TIE Line Programming
STEP 4:
ARTDN - Assign the TIE Line routes as shown below:
RT:1
1-OSGS
8-RLP
STEP 5:
ANPDL - Assign a number level for trunk access. Assign Connection Index, CI = N, H; Normal (N)
and Hooking (H). Number of Necessary Digits is usually 1 or 2. Busy Lamp Field is not activated.
STEP 6:
ARSCN - The Route Restriction Class (RSC) must be constructed to allow the station access to the
involved routes.
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Authorization Code - Tie Line Incoming Routes
:2
2-ONSG
:3
:2
15-LSG
:1
5-TF
:1
6-TCL
A-29
:1
7 L/T
:1
Page 41

Advertisement

Table of Contents
loading

Table of Contents