A-8
Programming
ASYD - System Data 1, Index 145. Timer Class 1 = 2 second.
For normal operation, assign 00H [RAM data is 94H]. Any call that uses AUTOMATIC RECALL
keeps one of the Attendant Console switched loops busy. Since there are six loops per Attendant
console, the maximum use of this feature is limited to that number. The AUTOMATIC RECALL
interval (normally set for 30 seconds) is a system option (System Data 1, Index 145) and can be varied
from two seconds to two minutes, in increments of two seconds.
System Data 1, Index 73, Bit 6 = 0.
Page 16
Automatic Recall
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1