NEC NEAX2400 IPX Programming Manual page 859

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

B-9
Service Conditions (cont'd)
3.
In a 3-way call in the mode where the conference button is pressed, the Attendant cannot perform BUSY
VERIFICATION.
4.
BUSY VERIFICATION cannot be established to a BUSY station when the station is:
a.) Dialing
b.) Listening to a tone
c.) Being rung
d.) Protected by DATA LINE SECURITY [D-12] [D-66]
e.) Being connected to an BUSY VERIFICATION Loop
f.) Activating a conflicting feature, such as:
ATTENDANT CAMP-ON WITH TONE INDICATION
BOSS-SECRETARY OVERRIDE-D
CALL HOLD
CALL TRANSFER
CALL WAITING-TERMINATING
CONSULTATION HOLD-ALL CALLS
DATA LINE SECURITY
DATA PRIVACY ON DEMAND
DIAL ACCESS TO ATTENDANT
EXECUTIVE RIGHT-OF-WAY
NON-EXCLUSIVE HOLD-D
PRIVACY RELEASE
THREE-WAY CALLING
VOICE CALL-D
g.) In a Modem Pooling connection,
h.) In a Data Call through a Data Adapter,
i.) In a Data Call through a Data Module.
In each of the above instances, the Attendant will receive reorder tone.
5.
Before the Attendant is added to an existing connection, a tone burst (.08 seconds) is applied to alert the
calling parties of the attendant's presence.
6.
BUSY VERIFICATION - CCIS and ATTENDANT LOCKOUT [A-5] are mutually exclusive features.
7.
BUSY VERIFICATION - CCIS can only be activated by the Attendant Console.
8.
It is possible to disable the continuous sending of warning tone during a BUSY VERIFICATION - CCIS
connection, via system data. Normally, the two-burst Warning Tone is repeated approximately every 15
seconds.
Interactions
1.
This feature is allowed whenever the destination telephone set is engaged in any state other than:
a.) A three-way connection
b.) An activated PRIVACY feature
c.) Connected to a route programmed to have Line/Trunk, Privacy, CDN 44:PRV
d.) Listening to a tone (dial tone, reorder tone, service set tone, busy tone, ringback tone).
2.
With ATTENDANT OVERRIDE [A-7], the following trunk types may be verified (busy or idle status):
a.) One-way incoming trunks,
b.) One-way outgoing trunk,
c.) Bothway trunk.
Page 816
Busy Verification - CCIS
term
term
term
[A-1][A-45]
[B-5D]
[C-6][C-6D]
[C-50][C-54][C-11][C-11D]
[C-12]
[C-58] [C-58D][C-17]
[D-12]
[D-68][D-17]
[D-71][D-2]
[E-8][E-8D][E-1]
[N-7D]
[P-18]
[T-2] in the mode where the
conference button is pressed.
[V-7D][V-2]
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1

Advertisement

Table of Contents
loading