NEC NEAX2400 IPX Programming Manual page 626

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

Programming (cont'd)
902-ORT
903-IRT
905-Sender 916-MFCR
909-DCFT 917-MFCS
TK:
TN:
RSC:
SFC:
STEP 4:
ARTD - Outgoing routes must be assigned as DP or DP/PB. Flag CDN 2:ONSG as data "1", DP or
data "3", DP/PB.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ARTDN - Outgoing routes must be assigned as DP or DP/PB. Flag CDN 2:ONSG as data "1", DP or
data "3", DP/PB.
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
Note:
in addition to ASYDL or ASYDN.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Pushbutton to Rotary Conversion
913-TCFT for ATT
915- Night ATT
919 to 926-Modem
Trunk Number
Tenant Number
Route Restriction Class
Service Feature Class
Note
P-6