Programming (cont'd)
System Data 1, Index 141. Assign the No Answer timer for incoming calls via the Attendant console. It
will then be forwarded to the next station according to SYS1, Index 145 timer. For 10 seconds, assign
00H. [RAM data is 35H.]
System Data 1, Index 145. Assign the time an incoming call via the Attendant Console will ring at the
CALL FORWARDING-DON'T ANSWER station before recalling to the Attendant console. For 30
seconds, assign 00H. [RAM data is 9FH.]
System Data 2, Index 6, Bit 7. Enable CALL FORWARDING-DON'T ANSWER via the Attendant
Console.
STEP 2:
ANPD - Reserve a number level for feature access and cancel. Assign Connection Index (CI) = N, H,
B; Normal, Hooking, and Busy (in order to be applicable to any feature assigned to this level). Assign
NND in accordance with a predetermined numbering plan.
STEP 3:
ASPA - Assign an access code to CALL FORWARDING-DON'T ANSWER entry, SID = 12, and to
CALL FORWARDING-DON'T ANSWER cancel, SID = 13. Assign CI for Normal (N) service.
STEP 4:
ASFC - Assign the stations to receive CALL FORWARDING-DON'T ANSWER a Service Feature
Class that allows SFI = 8.
STEP 5:
AKYD - For D
programmable line/feature key. Assign Type:Function:CALL FORWARD-DON'T ANSWER [22].
STEP 6:
ATNR - Allow tenant-to-tenant connection for Inter and Intra-tenant connections. Assign Tenant
Restriction Index (TRI) = 1. For this service feature to be set by the Attendant Console, assign Inter
and Intra-Tenant connection via the Attendant Console, TRI = 3. Also assign TRI = 0, station-to-
station calling.
CFI of either the Attendant Console or a station.
STEP 7:
ACFO - For tenant-wide CALL FORWARDING-DON'T ANSWER, assign CF = 2 for a destination
STEP 8:
ACFS - Call Forwarding can also be assigned via the ACFS command.
STEP 9:
ADAI - Assign NAT139, NAT140, NAT141 and NAT247 for Individual Call Forwarding - Don't
Answer Timer.
Service Version Index (SVI) allow SVI 1439, Individual Call Forwarding - Don't Answer Timer.
Binary:0/1=-/enable
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ASYDL - This data must be assigned to the node set Call Forwarding service.
System Data 1, Index 640: Assign the FPC of the node providing the attendant console.
Note 1:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
The data of the ASFC command is assigned to the node set Call Forwarding service.
Note 2:
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Call Forwarding - Don't Answer
term
sets, CALL FORWARDING-DON'T ANSWER may be assigned to a
Note 1