NEC NEAX2400 IPX Programming Manual page 113

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

A-121
Service Conditions (cont'd)
24.
The station setting Retain Conference can only cancel Retaining Conference or go on-hook. (No other
operation is available.) When the station goes on-hook, the RETAIN CONF lamp turns off.
25.
In case of trunk call origination, the billing is performed against the station which originated the trunk call
until the trunk releases. Therefore, there may be several billing messages sent for the same time for the
same station.
26.
During the 8-party conference, the CONF lamp remains lit.
27.
When this service is activated in an FCCS network, hardware conditions for connection trunks are as
shown below:
Programming
STEP 1:
ASYD - System data 1, index 92, bit 4 = 0/1. This enables tenant-to-tenant route restriction service.
System data 1, index 94, bit 0 = 0/1. This enables tenant-to-tenant restriction service.
System data 1, index 432, bits 0-3. Assign the first digit of the pilot number used for this service.
System data 1, index 432, bits 4-7. Assign the second digit of the pilot number.
System data 1, index 433, bits 0-3. Assign the third digit of the pilot number.
System data 1, index 433, bits 4-7. Assign the fourth digit of the pilot number.
System data 1, index 434, bits 0-3. Assign the fifth digit of the pilot number.
1 through 5 digits may be used; assign the bits accordingly. If a digit is not used, assign those bits as "0'.
Note:
If a bit is used for 0, see the following example:
System data 1, index 432 is A7,
System data 1, index 433 is 00,
System data 1, index 434 is x0.
STEP 2:
ASFC - For the SFC used by the CFTB-L or SP-1114 on PA-CFTB, assign SFI 32 = 1.
For the SFC used by stations that will use this feature, assign SFI 131 = 1. If you do not want certain
people to use this feature, make sure that SFI 131 = 0 in the SFC that the phone is programmed to.
STEP 3:
ASDT - assign stations to each level of the CFTB. Assign TEC = 27 for each level and ensure that the
CFTB levels are assigned in a separate tenant and separate SFC from non-CFTB levels.
STEP 4:
ASHC - Assign a STATION HUNTING - CIRCULAR group for stations programmed to LEN levels
1 through level 7 of the PA-CFTB circuit card(s). For more details, see the figure on the following
page.
Page 70
Add On Conference - 8 Party
PA-24DTR
PA-30DTT
SP-3010 Issue No. 13 or later (SW13-8: OFF)
SP-3012 Issue No. 8 or later
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1

Advertisement

Table of Contents
loading

Table of Contents