Programming (cont'd)
2: PB
3: DP/PB
12: D
13: Data terminal Via D
14: Hot Line
15: CAS Line
16: Data Terminal Via Data Module
18: Virtual Circuit
23: ISDN Terminal
26: VPS
27: Eight Conference Equipment
RSC:
Route Restriction Class (0-15)
For assignment of RSC, ARSC command.
SFC:
Service Feature Class (0-15)
For assignment of SFC, ASFC command.
STEP 2:
ASHP - Assign a Pilot hunting group using the last 7 circuits of PA-CFTB card. Circuit 0 of all PA-
CFTBs to be used for 8-party conference should be put into a Circular Hunt (ASHC).
STEP 3:
ASFC - Assign SFI 11 (Data Line Security) as "0".
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ASHPN - Assign a Pilot hunting group using the last 7 circuits of PA-CFTB card. Circuit 0 of all PA-
CFTBs to be used for 8-party conference should be put into a Circular Hunt (ASHCN).
STEP 2:
ALGSN - Assign stations as directed in ASDT.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Attendant-Controlled Conference
term
term
A-2
Page 5

Advertisement

Table of Contents
loading