A-125
Programming (cont'd)
System Data 1, Index 288, Bit 5. Expanded SMDR Output for SMDR A Apparatus. 0/1=Out/In
Service.
System Data 1, Index 290, Bit 5. Expanded SMDR Output for SMDR B Apparatus. 0/1=Out/In
Service.
System Data 1, Index 292, Bit 5. Expanded SMDR Output for SMDR C Apparatus. 0/1=Out/In
Service.
System Data 1, Index 294, Bit 5. Expanded SMDR Output for SMDR D Apparatus. 0/1=Out/In
Service.
System Data 1, Index 296, Bit 0. Output of Calling Number (ANI information). 0/1=Out/In Service.
Assign data "1".
System Data 1, Index 300, Bit 0. 0/1=-/Billing information is sent to the Main Node in Expanded
SMDR format in the case of CENTRALIZED BILLING - CCIS [C-55].
STEP 2:
ASFC - Assign a Service Feature Class that allows SFI 14 to stations allowed STATION MESSAGE
DETAIL RECORDING [S-10].
Assign a Service Feature Class that allows SFI 146 to analog stations allowed this service.
STEP 3:
ARTD - Assign route class data for the C.O. trunk.
15-LSG
When Calling Number is output to SMDR:
10-SMDR :1
STEP 4:
ATRK - Assign trunk data for the C.O. trunk.
STEP 5:
MBTK - Cancel the make busy of the C.O. trunk.
STEP 6:
AKYD - Assign Call ID Change Display key. Assign Type:Function: [113].
STEP 7:
ADSL - Assign ID CHG key; SN=4 (Communication in Progress), FKY=113 (Call ID Change
Display).
This command is used for assigning a function to each soft key on the D
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ARTDN - Assign route class data for the C.O. trunk.
15-LSG
When Calling Number is output to SMDR:
10-SMDR :1
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
Page 74
Analog Caller ID (Class SM)
:3
50-DPLY
:1
Note
:3
50-DPLY
:1
term
.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1