NEC NEAX2400 IPX Programming Manual page 585

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

N-2
N-2
General Description
This feature provides arrangements to route calls, usually directed to the ATTENDANT CONSOLE [A-3], instead
to a preselected station on a flexible, assignable basis within the system, when the Night Mode has been entered.
Operating Procedure
1.
Answering the operation is the same as that for NIGHT CONNECTION - FIXED [N-1].
2.
Each evening, before placing the ATTENDANT CONSOLE [A-3] into the Night Connection mode, the
Attendant programs CALL FORWARDING - ALL CALLS [C-5] from the fixed NIGHT CONNECTION
- FIXED station to the desired station.
Service Conditions
1.
The NIGHT CONNECTION - FLEXIBLE station may be programmed from either the ATTENDANT
CONSOLE [A-3] or the NIGHT CONNECTION - FIXED [N-1] station. Refer to CALL FORWARDING
- ALL CALLS
2.
NIGHT CONNECTION - FLEXIBLE: Arrangements are provided to route calls, normally directed to the
Attendant, to a preselected station line within the system when Night service is activated. Additionally,
incoming calls from specific non-DID exchange network trunks can be arranged to route to the specific
station line. The routings can be assigned on a flexible basis by the Attendant or NIGHT FIXED station
by use of the Call Forwarding feature and remain in effect until changed. For NIGHT CONNECTION -
FLEXIBLE to function, a NIGHT CONNECTION - FIXED telephone number must be assigned to the
trunk via the MAT [M-18]. In the event of a power failure, the assignments are not lost. The TAS [T-8]
answering capability is provided for Night calls not assigned to Night stations.
3.
When activating this feature within an FCCS network, the different destination for C.O. incoming calls
(Ring down) cannot be set at each tenant group.
Programming
STEP 1:
ACSI - NIGHT CONNECTION-FLEXIBLE is a combination of CALL FORWARDING-ALL
CALLS [C-5] and NIGHT CONNECTION-FIXED [N-1] features.
STEP 2:
ASFC - CLASS OF SERVICE-INDIVIDUAL [C-15]: The station chosen as the Night Connection-
Flexible station should be assigned a CLASS OF SERVICE-INDIVIDUAL [C-15] capable of
performing the Night station functions.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ACSIL - This command must be assigned to the node accommodating the COT. Assign the logical
route number (LGRT), trunk number, and Connection Service Index (CSI)=4 for DIT activated in
Night mode. Then assign the user group number (UGN) and Telephone Number to serve as the DIT
station.
Note:
The current data should also be set in addition the above-mentioned command. The command to be set to
the node accommodating the COT.
Page 542
Night Connection - Flexible
Night Connection - Flexible
[C-5]
for details.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1

Advertisement

Table of Contents
loading

Table of Contents